YMGI Specifications: DC Inverter Mini Split Heat Pump-Multiple Zone-(59)4 Outdoor Units 22 SEER
Model Units WMMS-30CH-V2B(59)4
Cooling Capacity Rating-Standard Comp. Speed Btu/h 18000
Min./Max. Cooling Capacity Btu/h 6998 / 21000
Heating Capacity Rating-Standard Comp. Speed Btu/h 19000
Min./Max. Heating Capacity Btu/h 7000 / 22600
Max. Allowed IDU Qty./Capacity Total # / Btu/h 2 / 30,000
EER W/W, (Btu/h)/W W/W 3.66 / 12.50
COP W/W, (Btu/h)/W W/W 3.66 / 12.50
SEER / HSPF - 22.00 / 10.50
Air Flow Volume CFM 1883
Sound Pressure / Power Level dB(A) 56 / 63
Power Supply V/Ph/Hz 208-230/1/60
Power Cable Conductor Minimum Size AWG AWG 14, Following NEC
Recommended HVAC Type Circuit Breaker Size Amp. 20
Power Input Cooling / Heating / Rated KW 1.44 / 1.52 / 2.80
Current Input Cooling / Heating / Rated A 6.26 / 6.61 / 12.42
Compressor Type, Model - Inverter Rotary, LD QXA- B141zF030A
Compressor Capacity / Input W 4320 / 1440
Compressor RLA / LRA A 10.82 / -
Compressor Thermal Protector KINGERSONS - Exterior 1NT11L—6233
Compressor Crankcase Heater W 25
Compressor Oil Type, Charge -, OZs RB68EP, 13.7
De-Ice/Snow Heater Power Input W 96
De-Ice/Snow Heater Current A 0.4
Fan Type / Qty. / Diameter-Height - Axial-flow / 1 /D550-H65mm
Motor Model / Type - LW60M-ZL, DC
Motor Insulation Class, Safe Class - E, IPX4
Fan Motor Drive Type, Speed - Director Drive, 630
Fan Motor Power Output / Input W 60 / -
Motor Full Load Amp (FLA) A -
Condenser Materials - Aluminum Fin-Copper Tube
Permissible Operating Pressure for the Discharge/Suction Sides PSI 600 / 360
High/Low Pressure Overload Protector PSI 580 / -
Cooling Operation  Ambient Temperature Range F 0 ~ 118
Heating Operation  Ambient Temperature Range F -4 ~ 75
Defrosting Method of Heat Pump in
Low Temperature Ambient
-- Automatic Reversing, Fan
Cycling
Pressure Maitenance Method in Low
Temperature Cooling
-- Automatic Fan Speed
Control, Cycling
Overload Protector - Current+Temperature
Designed for Climate Type, Moisture Protection - T1, IPX4
Refrigerant, Charge LBs R410A, 3.5
Metering Device KINGERSONS - Electronic expansion valve
Flare/Nut Valve Size-Liquid Inch 1/4, 1/4
Flare/Nut Valve Size-Gas Inch 3/8, 3/8
Min. Allowed Copper Line Length/Unit Ft. 15
Max. Allowed Copper Line Length-
outdoor to last indoor unit
Ft. 65
Max. Elevation Difference Allowed-
outdoor unit is below all indoor units
Ft. 35, Oil Trap is Not Needed
Max. Elevation Difference Allowed-
outdoor unit is above indoor units
Ft. 35, Oil Trap is Suggested
Every 18'
Max. Copper Line Length (all together) Ft. 130
No Additional Refrigerant Needs to be Added, If Copper Line Length Total is Less Than Ft. 60
Refrigerant Charge Rate, If Needed, by
Weight/Ft. of Extra Liquid Line Length
Ozs/Ft. 2.32
Dimension of Unit Outline (W×D×H) Inch 37.6x15.6x27.6
Dimension of Package (W×D×H) Inch 40.5x18.0x29.5
Weight-Net / Gross LBs 115 / 124
Loading Quantity (20’/40GP/40HQ) Units 81 / 171 / 171